Hot Sale DMD Series Lab Scale 2L~20L Glass Short Path Distillation
● Short condensing distance and few residue left after evaporation.
● High quality and heavy duty Borosilicate 3.3 glass for durability.
● Heating mantle with magnetic stirring function.
● Cold trap protects the vacuum pump from contamination and damage of vapors.
● Downward material drain port and distillation head with multiple sets of vigreux.
● Turnkey solution is provided which includes the glassware, magnet- ic stirring heating mantel, cold trap, chiller and other accessories.
DMD-02/DMD-05
DMD-02N/DMD-05N
DMD-10N/DMD-20N
The distillation head is equipped with Thermowellto enhance the sealing of the whole system.
Anti-reflux design at the front of the distillation head prevents excessive evaporation from backflow.
Needle vacuum valve design at the top to realize continuous collection without stopping. The receiving flask capacity can reach 1000ml, fully meet the requirements of short-range distillation collection.
The vacuum port is PTFE flange neck, with KF25 large diameter stainless steel vacuum bellows, so that can make the vacuum process is more efficient.
Distillation Head
The diameter of distillation head is increased to 80mm, and the larger space of jacket avoids heat loss during distillation.
Extended to 220mm condenser tube for full condensation, more efficient.
Electromagnetic Induction Heater
Electromagnetic induction heating, high thermal conversion 95%, Max temperature up to 380℃.
Receiving Flasks
Needle vacuum valve design at the top to realize continuous collection without stopping.
Cold Trap
The vacuum port is PTFE flange neck, with KF25 large diameter stainless steel vacuum bellows, so that can make the vacuum process is more efficient.
Model | DMD-02 | DMD-05 | DMD-02N | DMD-05N | DMD-10N | DMD-20N | |
Material |
Borosilicate Glass3.3 |
||||||
Heating Temperature |
Ambient to 380℃ |
||||||
Working Pressure |
Around 5 Pa |
||||||
Distillation Vessel | Volume(L) |
2 |
5 |
2 |
5 |
10 |
20 |
Receiving Vessel | Volume(mL) | 3x250mL | 3x250mL | 2x500mL (1 for Spare) | 2x1000mL ( 1 for Spare) |
4x2000mL ( 2 for Spare) |
4x2000mL (2 for Spare) |
Interface specification |
24/40 |
||||||
Cold Trap | DryIce Volume | 1L | 1L | 1L | 1L | 1L | 2x1L |
Receiving Flask |
1000ml |
||||||
Heating Mantle | Heating Power(w) |
650 |
1100 |
650 |
1100 |
2100 |
3000 |
Roating Speed(r/min) |
50-1800 |
||||||
Motor Power(w) |
40 |
||||||
Dimension (WxDxHmm) | 280*400*190 | 340*460*270 | 280*400*190 | 340*460*270 | 440*440*340 | 515*515*340 | |
Inner sleeve Diameter(mm) |
170 |
235 |
170 |
235 |
300 |
375 |
|
Inner sleeve Depth(mm) |
105 |
140 |
105 |
140 |
185 |
215 |
|
Vacuum Pump | Model |
SHZ-D III |
VRI-8 |
VRD-16 |
|||
Pumping Rate |
0.33 L/S (0.7CFM) |
2.22 L/S (5CFM) |
4.44 L/S (10CFM) |
||||
Ultimate Vacuum |
2 KPa |
0.1 Pa |
0.04 Pa |
||||
Power(w) |
180 |
550 |
550 |
||||
Optional/Vacuum Pump |
Model |
2XZ-2 |
VRD-8 |
VRD-24 |
|||
Pumping Rate |
2 L/S (4CFM) |
2.22 L/S (5CFM) |
6.67 L/S (14CFM) |
||||
Ultimate Vacuum |
0.07 Pa |
0.05 Pa |
0.04 Pa |
||||
Power(w) |
370 |
400 |
750 |
||||
Optional/ Diffusion Pump |
Model |
N/A |
FK-50 |
||||
Pumping Rate |
N/A |
80 L/S (170 CFM) |
|||||
Ultimate Vacuum |
N/A |
10-4Pa |
|||||
Power(w) |
N/A |
212 |
|||||
Optional/ Vacuum Gage |
Model |
N/A |
VRG-52 |
||||
Type |
N/A |
Pirani Gage |
|||||
Vacuum Detected Scope |
N/A |
5×10-2~1.0×105Pa |
|||||
Cooling Circulator | Model |
DC0506 |
SDC-6 |
||||
Cooling Temperature |
-5℃~100℃ |
||||||
Themally Conductive Liquid |
Anhydrous Ethanol or Ethyleneglycol:Water=55:45 |
||||||
General Voltage |
110v60Hz or 220V50/60Hz,1-Phase |